PET/CT Superior at Lesion Detection for Head and Neck Paragangliomas than Gold Standard MRI

By MedImaging International staff writers
Posted on 27 Jun 2024

Head and neck paragangliomas (HNPGLs) are rare neuroendocrine tumors that present significant diagnostic and therapeutic challenges due to their complex locations. Imaging plays an essential role in managing these tumors. Although MRI is typically used for preoperative assessment and follow-up, its capacity to distinguish between residual tumors and postoperative changes like scar tissue is somewhat limited. Now, a new imaging technique, 68Ga-DOTATATE PET/CT, offers a more precise differentiation between residual or recurrent tumors and post-surgical scar tissue in patients with HNPGLs, outperforming MRI. This method provides valuable functional details about the tumors, suggesting it could be crucial in enhancing strategies for preoperative and postoperative treatment planning in HNPGL patients.

Researchers at University Hospital Cleveland Medical Center (Cleveland, OH, USA) conducted a study involving 25 patients, some with a preoperative clinical suspicion of HNPGLs (five patients) and others with postoperative pathology-confirmed HNPGLs (20 patients). These patients underwent both 68Ga-DOTATATE PET/CT and MRI scans. A nuclear medicine physician with expertise in 68Ga-DOTATATE PET/CT reviewed all images. The results showed that 68Ga-DOTATATE PET/CT was superior in detecting lesions and more accurately defining the tumor extent in HNPGL patients compared to MRI. It also excelled in distinguishing between recurrent or residual tumors and postoperative scar tissue, demonstrating higher sensitivity and specificity than MRI alone.

“68Ga-DOTATATE PET/CT holds promise as a reliable imaging biomarker for HNPGLs, offering enhanced sensitivity and specificity compared to conventional imaging modalities,” said Patrick Wojtylak, MSHA, CNMT, Radiology System Manager for Nuclear Medicine at University Hospital Cleveland Medical Center. “Integrating 68Ga-DOTATATE PET/CT into the clinical management of HNPGLs can lead to more accurate diagnosis, better treatment planning, and improved patient outcomes.”

Related Links:
UH Cleveland Medical Center

Gold Member
X-Ray QA Meter
T3 AD Pro
Ultrasound System
Aplio go
Silver Member
Radiographic Positioning Equipment
2-Step Multiview Positioning Platform
Gold Member
X-Ray QA Meter
T3 RG Pro
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to MedImaging.net and get complete access to news and events that shape the world of Radiology.
  • Free digital version edition of Medical Imaging International sent by email on regular basis
  • Free print version of Medical Imaging International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of Medical Imaging International in digital format
  • Free Medical Imaging International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Radcal

Channels

Radiography

view channel
Image: The CT scanner prototype eliminates the need for physical compression of the breast (Photo courtesy of Quion Lowe and Lisa Dahm/U of A Cancer Center)

Novel Breast Cancer Screening Technology Could Offer Superior Alternative to Mammogram

Breast cancer represents 15.5% of new cancer cases and 7% of cancer-related deaths in the United States. Approximately 13.1% of women will be diagnosed with breast cancer during their lifetime.... Read more

Ultrasound

view channel
Image: CHEST has released a new clinical guideline on endobronchial ultrasound-guided transbronchial needle aspiration specimen processing and handling (Photo courtesy of CHEST)

New Guideline on Handling Endobronchial Ultrasound Transbronchial Needle Samples

Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) has become the standard procedure for the initial diagnosis and staging of lung cancer; however, there is limited guidance on... Read more

General/Advanced Imaging

view channel
Image: Heavy smokers can ben Image (2):	efit from lung cancer screening using low-dose CT (Photo courtesy of 123RF)

Low-Dose CT Screening for Lung Cancer Can Benefit Heavy Smokers

Lung cancer is often diagnosed at a late stage, with only about one-fifth to one-sixth of patients surviving five years after diagnosis. A new report now suggests that low-dose computed tomography (CT)... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more

Industry News

view channel
Image: The partnership will focus on integrating the Siemens Multitom Rax imaging system into the Medtronic AiBLE ecosystem for spine surgery (Photo courtesy of Siemens Healthineers)

Siemens and Medtronic Enter into Global Partnership for Advancing Spine Care Imaging Technologies

A new global partnership aims to explore opportunities to further expand access to advanced pre-and post-operative imaging technologies for spine care. Medtronic plc (Galway, Ireland) and Siemens Healthineers... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.