Ultrasound Offers New Approach to Measure Lung Fluid

By MedImaging International staff writers
Posted on 01 Jun 2017
A new study suggests that ultrasound may offer a noninvasive way to track and monitor pulmonary edema, which often affects patients with congestive heart failure (CHF).

Developed by researchers at North Carolina State University and the University of North Carolina, the new technique uses ultrasound multiple scattering and exploits the complexity of ultrasound propagation in the lung structure in order to characterize the micro-architecture of the lung parenchyma. The experimental setup consisted of a linear transducer array with an 8-MHz central frequency, which was placed in contact with the lung surface.

When conventional ultrasound waves hit air, the energy is scattered; this occurs multiple times in alveoli, resulting in an amorphous grey image with little useful information. This reflection process means that it takes an ultrasound’s echo much longer to return back to the ultrasound machine. But since no two ultrasound waves take the same path, their echoes take different amounts of time to return to the scanner. By examining all of the returning echoes and how they change over time, the extent to which the space between the alveoli is filled with fluid can be measured.

To test their approach, the researchers conducted two sets of experiments using rats. In the first set, the researchers used lung tissue that had been injected with saline solution to mimic fluid-filled lungs. The new approach allowed the researchers to quantify the amount of lung fluid to within one milliliter. In the second set, the researchers measured the mean distance between two ultrasound scattering events. They found that in fluid-filled lungs, the mean distance was 1,040 micrometers, whereas the mean distance in healthy lungs was only 332 micrometers. The study was published on March 18, 2017, in Ultrasound in Medicine and Biology.

“Historically, it has been difficult to use ultrasound to collect quantitative information on the lung, because ultrasound waves don’t travel through air– and the lung is full of air,” said senior author mechanical engineer Marie Muller, PhD, of NCSU. “However, we’ve been able to use the reflective nature of air pockets in the lung to calculate the amount of fluid in the lung. This is important, because one could potentially track this mean distance value as a way of determining how well pulmonary edema treatment is working.”

Pulmonary edema is fluid accumulation in the tissue and air spaces of the lungs, and is a cardinal feature of CHF. It leads to impaired gas exchange and may cause respiratory failure. It is due to either failure of the left ventricle of the heart to remove blood adequately from the pulmonary circulation (cardiogenic pulmonary edema), or an injury to the lung parenchyma or vasculature of the lung (noncardiogenic pulmonary edema). Treatment is focused on three aspects: improving respiratory function, treating the underlying cause, and avoiding further damage to the lung.

High-Precision QA Tool
DEXA Phantom
Adjustable Mobile Barrier
M-458
X-Ray Illuminator
X-Ray Viewbox Illuminators
Digital Radiography System (Ceiling Free)
Digix CF Series

Channels

General/Advanced Imaging

view channel
Image: Example snapshots of the photon energy density at t = 0.5, 0.7, 0.9, 1.1 nanoseconds (ns) on the y = 2.0 cm plane (Horie, S., Yajima, H., Abe, M. et al., Biomedical Engineering Letters (2026). DOI: 10.1007/s13534-026-00578-9)

AI Tool Enables Real-Time Diffuse Optical Tomography for Brain Lesion Detection

Diffuse optical tomography is a noninvasive imaging technique that uses near-infrared light to detect internal abnormalities such as cerebral hemorrhage and tumors. Its clinical utility for real-time ... Read more

Industry News

view channel
Image: MIM KineticID is 510(k)-pending software for dynamic PET imaging and kinetic modeling, enabling time-based radiotracer analysis for clinical and research decisions (Photo courtesy of GE Healthcare)

GE HealthCare Showcases AI-Enabled Nuclear Medicine Portfolio at SNMMI 2026

Nuclear medicine is expanding rapidly as health systems adopt theranostics and broaden access to radiopharmaceuticals, increasing demand for scalable operations and consistent diagnostic confidence.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.