Focused Ultrasound Scalpel Could Destroy Liver Tumors

By MedImaging International staff writers
Posted on 23 Mar 2017
Image: Focused ultrasound could treat tumors in moving organs, such as the liver (Photo courtesy of Fraunhofer MEVIS).
Image: Focused ultrasound could treat tumors in moving organs, such as the liver (Photo courtesy of Fraunhofer MEVIS).
A new technique that allows an ultrasound (US) beam to be refocused in synchronization with breathing could help treat liver tumors more effectively, while sparing surrounding healthy tissue.

The technique, developed by the Fraunhofer Institute for Medical Image Computing and SINTEF as part of the clinical translation of patient-specific planning and conducting of FUS treatment in moving organs (TRANS-FUSIMO) project, is based on real-time, predictive software that establishes liver position by magnetic resonance imaging (MRI) every tenth of a second, and calculates movement. The data is then sent to an US transducer equipped with more than 1,000 small transmitters that sits on the patient's stomach.

The transducer focuses the individual US transmission beams so that their waves converge precisely at a point as small as a grain of rice, resulting in a destructive effect at the focal point; the transmitters that face the ribs remain inactivated throughout the process. The MRI scanner controls the entire process, measuring the temperature in the liver and ensuring that the correct foci are sufficiently heated. The therapy is completely non-invasive and can be performed without anesthesia, and there are no wounds. A study describing preliminary results was presented at the annual European Radiology Congress (ECR), held during March 2017 in Vienna (Austria).

“Generating an image of the liver's position every tenth of a second is not fast enough to reliably direct the ultrasound beam. This is why we developed software that can see into the immediate future and calculate the next position of the treated region,” said mathematician Sabrina Haase, project manager at MEVIS. “The program determines the path for the focused ultrasound waves to reach the liver tumor even when the patient moves while breathing. Developing the software was quite challenging: it must run both highly reliably and in real time.”

“Patients with abdominal tumors must undergo multiple invasive interventions; MR-guided focused ultrasound can offer a genuine alternative to such interventions,” said radiologist Professor Mario Bezzi, MD, of La Sapienza University, who will participate in the clinical part of the TRANS-FUSIMO project. “The new therapy control system developed in the TRANS-FUSIMO project will be extraordinarily helpful in the clinical routine by allowing tumors to be destroyed very precisely and to guide the entire procedure effectively.”

High-intensity focused ultrasound (HIFU) technology is based on nonlinear mathematical optimization methods to analyze and simulate the propagation of sound in material. The information is then used to enhance the shape of an acoustic lens so that that US pressure is focused precisely on the location of the tissue to be ablated, while the surrounding tissue retains as little damage as possible.

Digital Intelligent Ferromagnetic Detector
Digital Ferromagnetic Detector
Half Apron
Demi
Digital Radiography System
DR-300
Biopsy Software
Affirm® Contrast

Channels

Imaging IT

view channel
Image: Researchers develop a vision-language model trained on large-scale data to generate clinically relevant findings from chest computed tomography images through visual question answering (Ms. Maiko Nagao from Meijo University, Japan)

Interactive AI Tool Supports Explainable Lung Nodule Assessment

Lung cancer is a leading cause of cancer mortality, and timely characterization of pulmonary nodules on chest computed tomography (CT) is essential for directing care. Interpreting nodule morphology demands... Read more

Industry News

view channel
Image: MIM KineticID is 510(k)-pending software for dynamic PET imaging and kinetic modeling, enabling time-based radiotracer analysis for clinical and research decisions (Photo courtesy of GE Healthcare)

GE HealthCare Showcases AI-Enabled Nuclear Medicine Portfolio at SNMMI 2026

Nuclear medicine is expanding rapidly as health systems adopt theranostics and broaden access to radiopharmaceuticals, increasing demand for scalable operations and consistent diagnostic confidence.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.