Lumbar Spine CT Radiation Dose Reduced by Decreasing Tube Voltage

By MedImaging International staff writers
Posted on 30 Apr 2013
An algorithm that takes the patient’s size into consideration can slash the radiation dose by 41% in lumbar spine computed tomography (CT) without losing the diagnostic quality of the images.

Researchers from Yeouido St. Mary’s Hospital (Seoul, Korea) examined 107 patients using semiautomated attenuation-based tube potential selection, which optimized tube potential at 100 kV rather than the standard 120 kV. Decreasing the voltage decreased the radiation dose from a mean of 21.78 mGy to a mean of 12.77 mGy, but it can increase the image noise (graininess), according to Dr. Junghyun Lim, lead author of the study.

The images were reconstructed using either the conventional filtered back projection or iterative reconstruction—a technique designed to decrease image noise. Two musculoskeletal radiologists reviewed the images and then scored them based on level of noise, visibility of structure and confidence of diagnosis. They concluded that irrespective of the reconstruction technique, the lower kilovoltage images were of diagnostic quality, according to Dr. Lim. “We conducted objective measurements of image noise as well,” noted Dr. Lim. “The objective measurements favored the images that had undergone iterative reconstruction.”

Dr. Lim noted that his facility performs between 140-150 lumbar CT scans each month. Based on the results of this study, “the routine lumbar spine CT exam is now conducted at 100 kV using filtered back projection,” he said.

The study’s findings were presented at the American Roentgen Ray Society (ARRS) annual meeting, held April 2013 in Washington DC (USA).

Related Links:
Yeouido St. Mary’s Hospital


Digital Intelligent Ferromagnetic Detector
Digital Ferromagnetic Detector
Multi-Use Ultrasound Table
Clinton
High-Precision QA Tool
DEXA Phantom
Digital X-Ray Detector Panel
Acuity G4

Channels

Nuclear Medicine

view channel
Image: This artistic representation illustrates how the drug candidate NECT-224 works in the human body (Photo courtesy of HZDR/A. Gruetzner)

Radiopharmaceutical Molecule Marker to Improve Choice of Bladder Cancer Therapies

Targeted cancer therapies only work when tumor cells express the specific molecular structures they are designed to attack. In urothelial carcinoma, a common form of bladder cancer, the cell surface protein... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.