CT Radiation Dose Reduced by 95% Using Image-Processing Algorithm

By MedImaging International staff writers
Posted on 17 Aug 2010
Perfusion CT scanning, an emerging imaging technology, received bad press in 2009 when a machine set to incorrect radiation levels overdosed hundreds of people in Los Angeles (CA, USA). In the wake of that incident, researchers excited by the technology's potential for diagnosing stroke, cancer, and possibly heart disease, have developed a method to reduce the amount of radiation involved in the procedure, which, when performed correctly, already involves very little risk.

"At the correct dose, there should be no injury,” said Dr. Cynthia McCollough, from at the Mayo Clinic (Rochester, MN, USA). "We believe in the clinical value of perfusion CT, so we're trying to lower the dose and reduce the stigma.” Dr. McCollough and her colleagues created a new image-processing algorithm that can give radiologists all of the information they need using as up to 20 times less radiation, depending on the diagnostic application. The research was presented July 20, 2010, at the 52nd annual meeting of the American Association of Physicists in Medicine (AAPM) in Philadelphia PA, USA.

A typical CT perfusion procedure lasts approximately half a minute and scans the same tissue many times, each scan at a low dose. These scans both reveal the internal anatomy of the patient and show how levels of a contrast agent, such as iodine injected into the bloodstream, change of over time. Changing concentrations of iodine can be used to calculate blood volume and flow in order to detect injuries to blood vessels or tumor responses to treatment.

The new adaptive algorithm compares these 20-30 scans and can distinguish between anatomic regions that do not change from moment to moment and those regions that carry the contrast agent--effectively reducing image noise while preserving iodine signal. The quality of each scan improves through nonlinear comparisons with scans acquired earlier and later in the exam.

"When we use very low doses, the noise gets so high that it's hard to tell what you are seeing,” said Dr. Juan Carlos Ramirez Giraldo. "With this algorithm, we're trying to maintain both the image quality, so that a doctor can recognize the anatomic structures, and the functional information, which is conveyed by analyzing the flow of the contrast agent over the many low dose scans.”

At the AAPM meeting, the researchers presented animal data showing the effectiveness of the technique. They have also started to process data from clinical brain perfusion CT exams in patients. "We're up to 15 or 20 cases that we've shown to the docs, and they're all giving us the thumbs up,” said Dr. McCollough.

Related Links:

Mayo Clinic


Silver Member
X-Ray QA Device
Accu-Gold+ Touch Pro
Post-Processing Imaging System
DynaCAD Prostate
Adjustable Mobile Barrier
M-458
Digital Color Doppler Ultrasound System
MS22Plus

Channels

Imaging IT

view channel
Image: QT Imaging’s latest breast imaging software adds enhanced reflection images by combining speed-of-sound and reflection data (photo courtesy of QT Imaging)

Breast Imaging Software Enhances Visualization and Tissue Characterization in Challenging Cases

Breast imaging can be particularly challenging in cases involving small breasts or implants, where image reconstruction and tissue characterization may be limited. Clinicians also need reproducible analysis... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.