We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
GLOBETECH PUBLISHING LLC

Download Mobile App




New Cardiac CT Technology Significantly Reduces Patient Radiation Exposure

By MedImaging International staff writers
Posted on 15 Mar 2010
In a new study, U.S. investigators have determined that an imaging exam of the heart using the latest generation of computed tomography (CT) technology exposes patients to as much as 91% less radiation than standard helical CT scanning.

"Coronary CT angiography has generated great enthusiasm in recent years, due to its diagnostic accuracy in assessing patients with known or suspected coronary artery disease,” said Andrew J. Einstein, M.D., Ph.D., assistant professor of clinical medicine in radiology and director of cardiac CT research at Columbia University Medical Center (New York, NY, USA). "However, that enthusiasm has been tempered by concern about the potentially high radiation dose received by patients.”

In CT imaging, numerous X-ray beams and a set of X-ray detectors rotate around the patient, measuring the amount of radiation being absorbed in the body. At the same time, the exam table moves through the scanner allowing the X-ray beam to follow a helical or spiral path. Many coronary CT angiography exams are conducted on 64-detector row CT scanners, which can image 4 cm at a time. The latest generation of CT technology, a 320-detector row volume CT scanner, can image 16 cm--or the entire length of the heart--in a single rotation and within a single heartbeat.

In his study, Dr. Einstein and a team of researchers from Columbia and the U.S. National Heart, Lung and Blood Institute (Bethesda, MD, USA) compared the radiation exposure incurred during a coronary CT angiography procedure using a 64-detector row helical scanning and volume scanning, using a 320-detector row volume CT scanner. Phantoms simulating the male and female body were imaged using six different scan modes.

Using standard 64-detector row helical scanning as the benchmark, the effective radiation dose was reduced by 91% from 35.4 millisieverts (mSv) to 4.4 mSv using optimized 320-detector row volume scanning. "By imaging the entire heart in one piece, volume scanning eliminates artifacts due to seams or gaps between image sections,” said Dr. Einstein. "Moreover, the X-ray tube is left on for only a brief duration, as little as 0.35 seconds.”

According to Dr. Einstein, state-of-the-art CT technology emphasizes optimal image resolution with the ability to lower radiation dose through a variety of features and scan modes that adjust and modulate the dose based on the specific needs of the individual patient. "As CT technology advanced from 16- to 64-slice capabilities, the radiation dose went up significantly,” he said. "Today, technology development is going in the opposite direction, reducing radiation exposure.”

Dr. Einstein emphasized that practitioners must pay careful attention to using the appropriate scan mode to obtain diagnostic information with the least amount of radiation exposure to the patient.

The study was published in the March 2010 issue of the journal Radiology.

Related Links:
Columbia University Medical Center
National Heart, Lung and Blood Institute


New
Post-Processing Imaging System
DynaCAD Prostate
Pocket Fetal Doppler
CONTEC10C/CL
Digital Intelligent Ferromagnetic Detector
Digital Ferromagnetic Detector
Wall Fixtures
MRI SERIES

Channels

Ultrasound

view channel
Image: The new implantable device for chronic pain management is small and flexible (Photo courtesy of The Zhou Lab at USC)

Wireless Chronic Pain Management Device to Reduce Need for Painkillers and Surgery

Chronic pain affects millions of people globally, often leading to long-term disability and dependence on opioid medications, which carry significant risks of side effects and addiction.... Read more

Nuclear Medicine

view channel
Image: The diagnostic tool could improve diagnosis and treatment decisions for patients with chronic lung infections (Photo courtesy of SNMMI)

Novel Bacteria-Specific PET Imaging Approach Detects Hard-To-Diagnose Lung Infections

Mycobacteroides abscessus is a rapidly growing mycobacteria that primarily affects immunocompromised patients and those with underlying lung diseases, such as cystic fibrosis or chronic obstructive pulmonary... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.