Combining Aiming Device with Laser Guidance Significantly Improves Target Accuracy during CT Procedures

By MedImaging International staff writers
Posted on 01 May 2023
Print article
Setup showing the laser guidance system in combination with the aiming device (Photo courtesy of Academic Radiology)
Setup showing the laser guidance system in combination with the aiming device (Photo courtesy of Academic Radiology)

Laser guidance has been shown to enhance needle placement during percutaneous interventions, but it has certain limitations. Despite laser guidance, needles must still be inserted manually and constantly illuminated to prevent clinicians from losing their mark. If a needle isn't adequately supported, its path may deviate during verification scans, necessitating additional sequences and increasing radiation exposure. A new study suggests that an aiming device could offer a solution to this issue.

Researchers at Medical University Innsbruck (Innsbruck, Austria) discovered that using an aiming device in conjunction with laser guidance during interventional CT procedures can boost targeting accuracy. They tested the effectiveness of an Atlas aiming device and compared its accuracy by performing 600 CT-guided punctures with and without targeting support on a plexiglass phantom. Planning CT data sets with 1.25, 2.5, and 5 mm slice thicknesses were obtained to evaluate needle accuracy and the impact of device usage on procedural times. Euclidean (ED) and normal distances (ND) were calculated at the target point.

When using the aiming device, the mean ND at the target for the 1.25, 2.5, and 5 mm slice thicknesses were 1.76 mm, 2.09 mm, and 1.93 mm, respectively. In comparison, freehand insertion results were 2.55 mm, 2.7 mm, and 2.31 mm. The accuracy of both ED and ND was significantly improved with the device at a slice thickness of 1.25 mm and 2.5 mm. However, the device led to a slight increase in procedure times, from 24.8 minutes without it to 29.8 minutes with it. Aiming devices, which stabilize needles, could be particularly helpful in reaching superficial or bone lesions and may also be useful for targeting deep lesions, according to the researchers. The team highlighted that their findings "indicate a clear, statistically significant superiority" in accuracy when using an aiming device and added that it should be technically feasible for adoption along with laser guidance systems already in clinical use.

“Additional support could be provided by a rigid aiming device to maintain the needle's steady position within the laser beam. In addition, a needle holder already aligned at the target allows needle insertion at a higher velocity, which may enhance position accuracy and reduce tissue damage,” concluded the researchers.

Computed Tomography System
Aquilion ONE / INSIGHT Edition
New
Digital Intelligent Ferromagnetic Detector
Digital Ferromagnetic Detector
New
Needle Guide Disposable Kit
Verza
Silver Member
X-Ray QA Meter
T3 AD Pro

Print article

Channels

Radiography

view channel
Image: AI can identify “mammographically-visible” types of interval cancers earlier by flagging them at the time of screening (Photo courtesy of ScreenPoint Medical)

AI Improves Early Detection of Interval Breast Cancers

Interval breast cancers, which occur between routine screenings, are easier to treat when detected earlier. Early detection can reduce the need for aggressive treatments and improve the chances of better outcomes.... Read more

MRI

view channel
Image: An MRI scan can reveal a heart’s functional age (Photo courtesy of 123RF)

New MRI Technique Reveals True Heart Age to Prevent Attacks and Strokes

Heart disease remains one of the leading causes of death worldwide. Individuals with conditions such as diabetes or obesity often experience accelerated aging of their hearts, sometimes by decades.... Read more

Nuclear Medicine

view channel
Image: In vivo imaging of U-87 MG xenograft model with varying mass doses of 89Zr-labeled KLG-3 or isotype control (Photo courtesy of L Gajecki et al.; doi.org/10.2967/jnumed.124.268762)

Novel Radiolabeled Antibody Improves Diagnosis and Treatment of Solid Tumors

Interleukin-13 receptor α-2 (IL13Rα2) is a cell surface receptor commonly found in solid tumors such as glioblastoma, melanoma, and breast cancer. It is minimally expressed in normal tissues, making it... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.