Adaptable Contrast Media Improves MRI Diagnostics

By MedImaging International staff writers
Posted on 12 Dec 2018
Print article
Image: Xenon filled vesicles provide higher contrast MRI scans than conventional contrast agents (Photo courtesy of Barth van Rossum / FMP).
Image: Xenon filled vesicles provide higher contrast MRI scans than conventional contrast agents (Photo courtesy of Barth van Rossum / FMP).
An adaptable protein structure that absorbs dissolved xenon in a self-regulating way allows for higher quality magnetic resonance imaging (MRI) scans with less contrast medium, claims a new study.

Developed by researchers at Leibniz-Forschungsinstitut für Molekulare Pharmakologie (FMP; Berlin, Germany) and the California Institute of Technology (Caltech; Pasadena, USA), the new contrast media is based on nanometric hollow protein structures produced by bacteria in order to regulate flotation depth, similar to a miniaturized swim bladder in fish. These so-called "gas vesicles" have a porous wall structure through which xenon gas can flow in and out, allowing them to elastically adjust their influence on the measured xenon.

Unlike conventional contrast media, the gas vesicles always absorb a fixed portion of the xenon present in the environment. This characteristic can be taken advantage of in MRI diagnostics, because more xenon gas must be used in order to obtain better images. While the concentration of a conventional contrast medium would need to be adjusted in order to achieve a change in signal for all xenon atoms, the gas vesicles automatically fill up with more xenon when this is offered.

As much more xenon is absorbed into the vesicles than with conventional contrast media, the image contrast is many times higher than the background noise, and image quality is significantly improved, allowing identification of disease markers that occur in relatively low concentrations. In animal studies, the researchers were able to produce MRI images with particle concentrations one million times lower than those of the contrast media currently employed. The study was published in the November 2018 issue of ACS Nano.

“We need new, improved methods, in which as little contrast medium as possible influences as much of the signal-transmitting substance as possible, typically water,” said senior author Leif Schroeder, PhD, director of the molecular imaging group at FMP. “They act like a kind of balloon, to which an external pump is attached. If the balloon is inflated by xenon atoms flowing into the gas vesicle its size does not change, but the pressure does increase, similar to a bicycle tire tube.”

Hyperpolarization of the nuclei of noble gases (usually using lasers) aligns them so that they become visible on an MRI scan. To detect specific cellular disease markers, they need to be bound to them for a short time. Gases used for medical imaging purposes include helium (He), argon (Ar), krypton (Kr), and xenon (Xe). The hyperpolarized spin state exists at very low spin temperatures, which leads to high magnetization of the spin ensemble, resulting in very high nuclear magnetic resonance signal intensity, which returns to thermal equilibrium by depolarization.

Related Links:
Leibniz-Forschungsinstitut für Molekulare Pharmakologie
California Institute of Technology

New
Digital Intelligent Ferromagnetic Detector
Digital Ferromagnetic Detector
3T MRI Scanner
MAGNETOM Cima.X
Digital Radiographic System
OMNERA 300M
Portable Color Doppler Ultrasound System
S5000

Print article

Channels

Radiography

view channel
Image: AI can identify “mammographically-visible” types of interval cancers earlier by flagging them at the time of screening (Photo courtesy of ScreenPoint Medical)

AI Improves Early Detection of Interval Breast Cancers

Interval breast cancers, which occur between routine screenings, are easier to treat when detected earlier. Early detection can reduce the need for aggressive treatments and improve the chances of better outcomes.... Read more

Nuclear Medicine

view channel
Image: In vivo imaging of U-87 MG xenograft model with varying mass doses of 89Zr-labeled KLG-3 or isotype control (Photo courtesy of L Gajecki et al.; doi.org/10.2967/jnumed.124.268762)

Novel Radiolabeled Antibody Improves Diagnosis and Treatment of Solid Tumors

Interleukin-13 receptor α-2 (IL13Rα2) is a cell surface receptor commonly found in solid tumors such as glioblastoma, melanoma, and breast cancer. It is minimally expressed in normal tissues, making it... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.