We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
GLOBETECH PUBLISHING LLC

Download Mobile App




Digital Radiography Detectors Provide Increased Sensitivity for Higher Image Quality

By MedImaging International staff writers
Posted on 03 Oct 2011
Print article
Three new flat panel digital radiography (DR) detectors have been designed to extend the mobility, versatility, and high-resolution diagnostic imaging capabilities available to medical institutions.

Each of the new Canon (Tokyo, Japan) DR detectors has an improved resolution of 125 μm and an increased level of sensitivity to deliver higher image quality. They have been developed to improved portability and ease of use for the benefit of users, as well as convenience and improved imaging capabilities that directly benefit the patient.

As Canon’s first compact wireless DR system, the CXDI-80C Wireless builds on the success of Canon’s CXDI-70C Wireless DR system, while achieving reductions in size and weight. Combining versatility, very high image quality and sensitivity in a more convenient and compact size, the CXDI-80C Wireless is a small area detector that delivers added convenience and freedom during diagnostic examinations.

With its lightweight but strong design and an imaging area of 27 cm x 35 cm, which is similar in size to a traditional imaging cassette, the CXDI-80C Wireless is suitable for extremity imaging and has the added benefit that it can fit into an incubator X-ray cassette tray in neonatal intensive care units (NICU). When the CXDI-80C Wireless is used with the CXDI-70C Wireless DR system, the combination of sophisticated wireless DR detectors cover all high quality imaging requirements in low dose general radiography, including imaging of the skull, chest, abdomen, and extremities.

With their new glass substrate, image quality, and portability, the new Canon CXDI-501 series DR detectors allow radiographers to deliver efficient diagnosis and excellent patient care, with the added convenience that low detector weight and very slim design brings.

Versatility is increased as the Canon CXD-501 series detectors not only include a detachable cable but can also fit into most existing bucky cassette trays. The CXDI-501C and CXDI-501G DR systems feature a 35 cm x 43 cm imaging area and each weigh 3.1 kg. Providing excellent X-ray photon conversion efficiency, the CXDI-501 series detectors also integrate a high quality 9.5 megapixel Canon LANMIT (large area new-MIS [microwave imager-sounder] sensor and TFT [thin-film transistor]). image sensor with a pixel pitch of 125 μm and are available with either a cesium iodide (CsI) scintillator (CXDI-501C) or gadolinium oxysulphide (GOS) scintillator (CXDI-501G).

The CXDI-501 DR system produces ultra-fast image output, allowing radiographers and medical staff to view an image only three seconds after X-ray exposure. The latest Canon CXDI-NE imaging software, also supplied, helps users to streamline workflow by reducing the number of operational steps required to complete a patient examination to the absolute minimum, automating many actions, and presenting data in a clear and concise manner.

The CXDI-501C/G and the CXDI-80C Wireless detectors will be available in the fourth quarter of 2011.

Related Links:
Canon

Portable Color Doppler Ultrasound Scanner
DCU10
New
Diagnostic Ultrasound System
DC-80A
New
Cylindrical Water Scanning System
SunSCAN 3D
New
Biopsy Software
Affirm® Contrast

Print article

Channels

MRI

view channel
Image: In brains of control mice (left) and PD mice (right), from bottom to top: neuronal activity in a representative animal (Photo courtesy of Ruxanda Lungu/FC)

Simple Brain Scan Diagnoses Parkinson's Disease Years Before It Becomes Untreatable

Parkinson's disease (PD) remains a challenging condition to treat, with no known cure. Though therapies have improved over time, and ongoing research focuses on methods to slow or alter the disease’s progression,... Read more

Nuclear Medicine

view channel
Image: In vivo imaging of U-87 MG xenograft model with varying mass doses of 89Zr-labeled KLG-3 or isotype control (Photo courtesy of L Gajecki et al.; doi.org/10.2967/jnumed.124.268762)

Novel Radiolabeled Antibody Improves Diagnosis and Treatment of Solid Tumors

Interleukin-13 receptor α-2 (IL13Rα2) is a cell surface receptor commonly found in solid tumors such as glioblastoma, melanoma, and breast cancer. It is minimally expressed in normal tissues, making it... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.