We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us

Download Mobile App




Ultrasound Color Doppler Twinkling May Aid Detection of Breast Biopsy Markers

By MedImaging International staff writers
Posted on 08 Sep 2022
Image: Ultrasound color Doppler twinkling may aid the detection of certain biopsy markers (Photo courtesy of Pexels)
Image: Ultrasound color Doppler twinkling may aid the detection of certain biopsy markers (Photo courtesy of Pexels)

Ultrasound color Doppler twinkling may aid the detection of certain biopsy markers in metastatic axillary nodes that resume normal morphology after neoadjuvant systemic therapy, according to a new study.

Researchers at the Mayo Clinic (Rochester, MN, USA) evaluated 35 commercial breast biopsy markers for twinkling artifact in various experimental conditions, including scanning medium (solid gel phantom, ultrasound coupling gel, cadaveric breast), transducer (ML6-15, 9L, C1-6), and embedding material (present vs. absent). Markers were then assigned twinkling scores from 0 (confident in no twinkling) to 4 (confident in exuberant twinkling); score ≥3 represented actionable twinkling. Ultimately, three breast biopsy markers - Cork, Q, and MRI (Flex) - exhibited actionable ultrasound twinkling for ≥2 transducers in cadaveric breast. Additionally, surface roughness was significantly higher for markers with than without actionable twinkling for the C1-6 (median values: 0.97 vs. 0.35, p=.02) and 9L (1.75 vs. 0.36; p=.002) transducers.

Noting that certain breast biopsy markers exhibited actionable twinkling (i.e., sufficient confidence to rely solely on twinkling for target localization) in cadaveric breast, “twinkling was observed with greater confidence for C1-6 and 9L than ML6-15 transducer,” wrote first author Christine U. Lee, MD, PhD, from the department of radiology at Mayo Clinic. “Actionable twinkling was associated with higher marker surface roughness.”

“The use of twinkling artifact to help detect biopsy markers by ultrasound could impact breast radiologists in performing preoperative localization procedures after NST,” the authors concluded, thus impacting breast surgeons in performing intraoperative localization.

Related Links:
Mayo Clinic 

Silver Member
X-Ray QA Device
Accu-Gold+ Touch Pro
Portable X-ray Unit
AJEX140H
High-Precision QA Tool
DEXA Phantom
Digital Radiographic System
OMNERA 300M

Channels

Imaging IT

view channel
Image: Researchers develop a vision-language model trained on large-scale data to generate clinically relevant findings from chest computed tomography images through visual question answering (Ms. Maiko Nagao from Meijo University, Japan)

Interactive AI Tool Supports Explainable Lung Nodule Assessment

Lung cancer is a leading cause of cancer mortality, and timely characterization of pulmonary nodules on chest computed tomography (CT) is essential for directing care. Interpreting nodule morphology demands... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.