MDCT Radiation Dose Can Be Reduced by the Use of Pediatric Breast Shields

By MedImaging staff writers
Posted on 26 Feb 2008
Image: 3-D CT of a child’s head, showing the skin surface (orange) and the skull (blue) (Photo courtesy of Philippe Plailly / SPL).
Image: 3-D CT of a child’s head, showing the skin surface (orange) and the skull (blue) (Photo courtesy of Philippe Plailly / SPL).
Using breast shields during pediatric chest multi-detector computed tomography (MDCT) imaging reduces radiation dose and minimally increases image noise, according to a recent study.

The study was conducted by researchers at Duke University Medical Center (Durham, NC, USA) and the University of Arkansas for Medical Sciences and Arkansas Children's Hospital (Little Rock, USA).

"It's important for radiologists to limit dose in CT, especially to children, and especially to radiosensitive regions, such as breast tissue; and radiologists should be familiar with strategies to do this,” said Donald P. Frush, M.D., lead author of the study. "Two strategies are breast shielding, and the other is automatic tube current modulation [ATCM]. However, the combination of the shield and ATCM may not be effective since the equipment might increase the dose to penetrate the shield. We wanted to see if there was a way to circumvent this, and in fact, there was: by placing the shields on the patient after the topogram [scout] from which the tube current would be modulated. This was tested using a GE [Healthcare] scanner [Chalfont St. Giles, UK] and it may not work with other scanners.”

Researchers performed MDCT on the chest an anthropomorphic phantom that represented a five-year-old child. They obtained two scans in each of four sequences: without the shield, with a two-ply bismuth shield, ATCM after placement of the shield, and ATCM before placement of the shield.

The study revealed that the bismuth breast shield reduced radiation dose to the breast by 26%, and shielding and ATCM reduced the dose by 52%. The study also showed that multiple organ doses were lowest when the shield was placed after the scout radiograph was obtained. With this technique, image noise increased, but the images were still of good quality.

"Radiologists need to understand their equipment's ATCM before using shielding. Parents should inquire about dose reduction strategies before their child undergoes a CT scan, and physicians who refer pediatric patients to radiologists should understand that research is continuing to minimize radiation dose in CT,” said Dr. Frush.

The full results of this study appear in the January 2008 issue of the American Journal of Roentgenology.


Related Links:
Duke University Medical Center
Arkansas Children's Hospital
Mobile X-Ray System
K4W
Mammography System (Analog)
MAM VENUS
Ultrasonic Pocket Doppler
SD1
40/80-Slice CT System
uCT 528

Channels

Nuclear Medicine

view channel
Image: This artistic representation illustrates how the drug candidate NECT-224 works in the human body (Photo courtesy of HZDR/A. Gruetzner)

Radiopharmaceutical Molecule Marker to Improve Choice of Bladder Cancer Therapies

Targeted cancer therapies only work when tumor cells express the specific molecular structures they are designed to attack. In urothelial carcinoma, a common form of bladder cancer, the cell surface protein... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.