Combining Technologies with SPECT Provides High-Quality Images of Small Tumors

By MedImaging International staff writers
Posted on 21 Jul 2009
A new study shows that combining high resolution and high-sensitivity collimation provides better quality images when using single photon emission computed tomography (SPECT) scans.

Collimators--devices that filter a stream of rays so that only those moving parallel to a specified direction are allowed through--are used in SPECT imaging because it is not yet possible to focus radiation with such short wavelengths into an image with the use of lenses. Using the two types of collimation in tandem is particularly effective for better imaging of small tumors, the study indicates.

"SPECT is an important tool in molecular imaging because of its ability to provide accurate images of what is going on in the body without the need for invasive procedures such as surgery,” said Dr. Roel Van Holen, a researcher in the department of electronics and information systems of Ghent University (Ghent, Belgium; www.ugent.be), and lead author of the study. "However, researchers have had to make tradeoffs in SPECT image quality, especially in imaging very small tumors. Our research is exciting because it shows that combining high-resolution and high-energy collimators can improve SPECT's ability to image small tumors.”

Researchers have established that SPECT image quality generally improves when using collimators with higher sensitivity than traditional low-energy high-resolution (LEHR) collimators. However, this is not the case when small tumors are being imaged. In these cases, LEHR actually provides better images.

The new study combined a high-resolution collimator with a high-sensitivity collimator. A dual-head SPECT camera with three different collimator settings was simulated using the GATE (GEANT4 application for tomographic emission) Monte Carlo simulator. The results indicated that SPECT image quality was better with the mixed collimation than it was by using only high-resolution or only high-sensitivity collimation.

The researchers presented their study at SNM's (formerly the Society of Nuclear Medicine) 56th annual meeting, held in Toronto, Canada, in June 2009.

Related Links:
Ghent University


3T MRI Scanner
MAGNETOM Cima.X
Ultrasound Table
Women’s Ultrasound EA Table
Portable Color Doppler Ultrasound System
S5000
Ultrasound Imaging System
P12 Elite

Channels

Ultrasound

view channel
Image: The new implantable device for chronic pain management is small and flexible (Photo courtesy of The Zhou Lab at USC)

Wireless Chronic Pain Management Device to Reduce Need for Painkillers and Surgery

Chronic pain affects millions of people globally, often leading to long-term disability and dependence on opioid medications, which carry significant risks of side effects and addiction.... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.