Combining Aiming Device with Laser Guidance Significantly Improves Target Accuracy during CT Procedures

By MedImaging International staff writers
Posted on 01 May 2023
Print article
Setup showing the laser guidance system in combination with the aiming device (Photo courtesy of Academic Radiology)
Setup showing the laser guidance system in combination with the aiming device (Photo courtesy of Academic Radiology)

Laser guidance has been shown to enhance needle placement during percutaneous interventions, but it has certain limitations. Despite laser guidance, needles must still be inserted manually and constantly illuminated to prevent clinicians from losing their mark. If a needle isn't adequately supported, its path may deviate during verification scans, necessitating additional sequences and increasing radiation exposure. A new study suggests that an aiming device could offer a solution to this issue.

Researchers at Medical University Innsbruck (Innsbruck, Austria) discovered that using an aiming device in conjunction with laser guidance during interventional CT procedures can boost targeting accuracy. They tested the effectiveness of an Atlas aiming device and compared its accuracy by performing 600 CT-guided punctures with and without targeting support on a plexiglass phantom. Planning CT data sets with 1.25, 2.5, and 5 mm slice thicknesses were obtained to evaluate needle accuracy and the impact of device usage on procedural times. Euclidean (ED) and normal distances (ND) were calculated at the target point.

When using the aiming device, the mean ND at the target for the 1.25, 2.5, and 5 mm slice thicknesses were 1.76 mm, 2.09 mm, and 1.93 mm, respectively. In comparison, freehand insertion results were 2.55 mm, 2.7 mm, and 2.31 mm. The accuracy of both ED and ND was significantly improved with the device at a slice thickness of 1.25 mm and 2.5 mm. However, the device led to a slight increase in procedure times, from 24.8 minutes without it to 29.8 minutes with it. Aiming devices, which stabilize needles, could be particularly helpful in reaching superficial or bone lesions and may also be useful for targeting deep lesions, according to the researchers. The team highlighted that their findings "indicate a clear, statistically significant superiority" in accuracy when using an aiming device and added that it should be technically feasible for adoption along with laser guidance systems already in clinical use.

“Additional support could be provided by a rigid aiming device to maintain the needle's steady position within the laser beam. In addition, a needle holder already aligned at the target allows needle insertion at a higher velocity, which may enhance position accuracy and reduce tissue damage,” concluded the researchers.

Gold Supplier
128 Slice CT Scanner
Supria 128
Gold Supplier
Conductive Gel
Tensive
New
Afterloader For Brachytherapy
Flexitron
New
Diagnostic Ultrasound System
DRE Crystal 4P

Print article
Sun Nuclear -    Mirion

Channels

Radiography

view channel
Image: Radiologists outperformed AI in identifying lung diseases on chest X-ray (Photo courtesy of RSNA)

Radiologists Beat AI in Detecting Common Lung Diseases on Chest X-Rays

Chest X-rays are frequently used for diagnosis, but it takes a lot of training and expertise to read these images correctly. Although the Food and Drug Administration (FDA) has approved some artificial... Read more

Ultrasound

view channel
Image: The new device targets ultrasound waves to precise spots in the brain (Photo courtesy of WUSTL)

Anatomically Precise Ultrasound-Based Technique to Enable Noninvasive Biopsies for Brain Tumors

The blood-brain barrier serves as a protective wall, keeping the brain safe from harmful elements like viruses and toxins in the blood. This makes it challenging for doctors to obtain molecular and genetic... Read more

Nuclear Medicine

view channel
Image: Imaging entire body instead of only the primary cancer site can provide a total estimate of HER2 expression (Photo courtesy of 123RF)

Whole-Body PET/CT Predicts Response to HER2-Targeted Therapy in Metastatic Breast Cancer Patients

Around 20% of women diagnosed with breast cancer show overexpression of human epidermal growth factor receptor 2 (HER2), making it a key therapy target for new as well as recurring cases.... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more

Industry News

view channel
Image: The partnership combines best-in-class AI-powered technologies for musculoskeletal imaging workflows (Photo courtesy of ImageBiopsy Lab)

AI-Powered Technologies to Aid Interpretation of X-Ray and MRI Images for Improved Disease Diagnosis

Musculoskeletal (MSK) conditions impact more people worldwide than issues related to the circulatory or respiratory systems. Even so, diagnostic procedures for these conditions often still lean on outdated... Read more
Copyright © 2000-2023 Globetech Media. All rights reserved.