3D Mammography Significantly Reduces Breast Biopsies

By MedImaging International staff writers
Posted on 01 Apr 2019
Print article
Image: An 8-mm indeterminate mass on FFDM, which was interpreted as benign on DBT (Photo courtesy of LBORO).
Image: An 8-mm indeterminate mass on FFDM, which was interpreted as benign on DBT (Photo courtesy of LBORO).
Digital breast tomosynthesis (DBT) considerably reduces the number of women who undergo breast biopsy following an abnormal mammogram, according to a new study.

Researchers at Seacroft Hospital (Leeds, United Kingdom) and Loughborough University (LBORO; United Kingdom) conducted a prospective study that included 30,933 women who had a full-field digital mammography (FFDM) screening between 2015 and 2016; recalled women also underwent DBT and biopsy. Readers blinded to biopsy results analyzed DBT images in isolation and then in conjunction with FFDM images, and any additional mammographic or ultrasound images. The aim of the study was to evaluate the benign biopsy rate of DBT versus that of FFDM.

The results revealed that 1,470 women were recalled for further imaging (a 4.8% recall rate) to assess an abnormality. A final recall group of 827 women (after exclusions) required 571 biopsies, for a biopsy rate of 69%. While biopsy detected 142 cancers, in the other 429 biopsies performed, the suspicious lesion was not cancerous, a benign biopsy rate of 75%. Inclusion of DBT would have reduced the number of biopsies performed on recalled women from 571 to 298--while still detecting the 142 cancers--for a biopsy rate of 36%, and a benign biopsy rate of 52%. The study was published on March 19, 2019, in Radiology.

“The thin slice images of the breast taken with DBT reduce the effect of tissue overlap, which often leads to cancers being missed or to women who don't have breast cancer being recalled for diagnostic imaging,” said lead author Nisha Sharma, MB, ChB, director of breast screening at Seacroft Hospital. “DBT allows for improved reader accuracy and confidence in determining if a mammographic abnormality is concerning or not, and reduces harm to women through fewer false positive biopsies without any reduction in the cancer detection rate.”

DBT acquires multiple images over a limited angular range to produce a set of reconstructed images, which can then be viewed individually or sequentially in a cine loop, and in a three-dimensional (3D) image of the breast, which can viewed in narrow slices, similar to CT scans. While in conventional 2D mammography overlapping tissues can mask suspicious areas, 3D images eliminate the overlap, making abnormalities easier to recognize. It is estimated that 3D DBT will replace conventional mammography within ten years.

Related Links:
Seacroft Hospital
Loughborough University

Gold Member
Solid State Kv/Dose Multi-Sensor
AGMS-DM+
Dose Area Product Meter
VacuDAP
New
Silver Member
Mobile X-Ray Barrier
Lead Acrylic Mobile X-Ray Barriers
Under Table Shield
3 Section Double Pivot Under Table Shield

Print article

Channels

Ultrasound

view channel
Image: Structure of the proposed transparent ultrasound transducer and its optical transmittance (Photo courtesy of POSTECH)

Ultrasensitive Broadband Transparent Ultrasound Transducer Enhances Medical Diagnosis

The ultrasound-photoacoustic dual-modal imaging system combines molecular imaging contrast with ultrasound imaging. It can display molecular and structural details inside the body in real time without... Read more

Nuclear Medicine

view channel
Image: PET/CT of a 60-year-old male patient with clinical suspicion of lung cancer (Photo courtesy of EJNMMI Physics)

Early 30-Minute Dynamic FDG-PET Acquisition Could Halve Lung Scan Times

F-18 FDG-PET scans are a way to look inside the body using a special dye, and these scans can be either static or dynamic. Static scans happen 60 minutes after the dye is administered into the body, showing... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more

Industry News

view channel
Image: The acquisition will expand IBA’s medical imaging quality assurance offering (Photo courtesy of Radcal)

IBA Acquires Radcal to Expand Medical Imaging Quality Assurance Offering

Ion Beam Applications S.A. (IBA, Louvain-La-Neuve, Belgium), the global leader in particle accelerator technology and a world-leading provider of dosimetry and quality assurance (QA) solutions, has entered... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.