CT System Reconstructs Breast Specimens Digitally

By MedImaging International staff writers
Posted on 06 Jun 2018
Print article
Image: The VisionCT system scans 360-degree images of excised lesions (Photo courtesy of Faxitron Bioptics).
Image: The VisionCT system scans 360-degree images of excised lesions (Photo courtesy of Faxitron Bioptics).
A computerized tomography (CT) specimen imaging system provides detailed margin assessment by reconstructing a navigable three-dimensional (3D) render in real time.

The Faxitron Bioptics (Tucson, AZ, USA) VisionCT system is a fully automated 3D specimen cabinet system equipped with a motorized, 360-degree rotating platform that can capture up to six high-resolution images per second. The system reconstructs breast specimens in up to 1,024 slices at a standard slice thickness of 100 micron, allowing for complete and detailed radiographic assessment of margin status, in addition to immediate traditional orthogonal images. Users can review orthogonal images as the specimen is being scanned and reconstructed in real time, with automated magnification allowing for optimal resolution of any specimen size up to 11 cm in diameter.

The system is turn-key and fully automated, with no additional x-ray shielding, specialized knowledge, or manual specimen repositioning required; the specimen is simply positioned in disposable holder, placed in a container in the chamber, and scanned. Fast, versatile imaging allows for presentation of both 2D and orthogonal images in less than 30 seconds, with full 3D reconstruction of the whole specimen in less than four minutes, including automatic metal artifact correction to minimize interference. DICOM images are automatically stored to PACS and saved to local or network drive, with images instantaneously displayed on the 24" high-resolution monitor.

“As imaging innovations in breast screening continue to drive earlier detection of abnormalities in breast tissue, there is a parallel need for ongoing improvements in methods for assessing and confirming specimen margin status during surgery,” said Donogh O’Driscoll, CFO and COO of Faxitron Bioptics. “VisionCT gives providers a clearer, more detailed view of breast specimen margin status than ever before. We’ve spent decades pioneering new technologies that contribute to a higher standard of care for patients and are proud that legacy continues as we introduce VisionCT to the market.”

Planar specimen radiography is the current standard of care in intraoperative margin assessment. This requires the surgeon and radiologist to attempt to visualize microcalcifications or lesion in 3D space by viewing images individually, but in relation to one another. The challenge is that both collecting and visualizing the images are manual processes, and therefore may not always be standard practice.

Gold Member
Solid State Kv/Dose Multi-Sensor
AGMS-DM+
Dose Calibration Electrometer
PC Electrometer
New
Brachytherapy Planning System
Oncentra Brachy
MRI System
uMR 588

Print article

Channels

Radiography

view channel
:	Image: The AI model could be a valuable adjunct to human radiologists in breast cancer diagnoses and risk prediction (Photo courtesy of 123RF)

AI Model Predicts 5-Year Breast Cancer Risk from Mammograms

Approximately 13% of U.S. women, or one in every eight, are predicted to develop invasive breast cancer over their lifetime, with 1 in 39 women (3%) succumbing to the illness, according to the American... Read more

Nuclear Medicine

view channel
Image: The AI system uses scintigraphy imaging for early diagnosis of cardiac amyloidosis (Photo courtesy of 123RF)

AI System Automatically and Reliably Detects Cardiac Amyloidosis Using Scintigraphy Imaging

Cardiac amyloidosis, a condition characterized by the buildup of abnormal protein deposits (amyloids) in the heart muscle, severely affects heart function and can lead to heart failure or death without... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more

Industry News

view channel
Image: Samsung Medison CEO Mr. Yongkwan Kim and Bracco Imaging CEO Dr. Fulvio Renoldi Bracco endorsed a MoU agreement (Photo courtesy of Bracco Group)

Samsung and Bracco Enter Into New Diagnostic Ultrasound Technology Agreement

Samsung Medison (Seoul, South Korea) and Bracco Imaging (Milan, Italy) have entered into a Memorandum of Understanding (MoU) agreement to pioneer a new area for diagnostic ultrasound devices and contrast agents.... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.