Optical Coherence Tomography Device Visualizes Bacteria Behind the Eardrum

By MedImaging International staff writers
Posted on 21 Jun 2012
Clinicians can now get a glimpse behind the eardrum to better diagnose and treat chronic ear infections, due to a new medical imaging technology. The new device could lead to a new range of noninvasive, three-dimensional (3D) diagnostic imaging tools for primary-care physicians.

The researchers, led by University of Illinois at Urbana-Champaign (U of I; Champaign, IL, USA) electrical and computer engineering professor, Dr. Stephen Boppart, published their findings in online May 28, 2012, in the journal Proceedings of the National Academy of Sciences of the USA (PNAS) the week of May 28, 2012.

Ear infections are the most typical complaints that pediatricians treat. Chronic ear infections can damage hearing and often require surgery to place drainage tubes in the eardrum, and problems can persist into adulthood. Studies have found that patients who suffer from chronic ear infections may have a film of bacteria or other microorganisms that collects behind the eardrum, very similar to dental plaque on unbrushed teeth. Finding and monitoring these so-called biofilms are vital for effectively identifying and treating chronic ear infections.

“We know that antibiotics don’t always work well if you have a biofilm, because the bacteria protect themselves and become resistant,” Dr. Boppart said. “In the presence of a chronic ear infection that has a biofilm, the bacteria may not respond to the usual antibiotics, and you need to stop them. But without being able to detect the biofilm, we have no idea whether or not it’s responding to treatment.”

However, middle-ear biofilms are difficult to diagnose. A physician looking through a standard otoscope sees only the eardrum’s surface, not the bacteria-seeded biofilm lurking behind it waiting to bloom into infection. Invasive tests can provide evidence of a biofilm, but are unpleasant for the patient and cannot be used routinely. The new device is an application of a technique called optical coherence tomography (OCT), a noninvasive imaging system devised by Dr. Boppart’s group. It uses beams of light to collect high-resolution, three-dimensional tissue images, scanning through the eardrum to the biofilm behind it--much like ultrasound imaging, but using light.

“We send the light into the ear canal, and it scatters and reflects from the tympanic membrane and the biofilm behind it,” said graduate student Cac Nguyen, the lead author of the study. “We measure the reflection, and with the reference light we can get the structure in depth.”

The single scan is performed in a fraction of a second--speed is a necessity for treating wiggling young children--and images a few millimeters deep behind the eardrum. Therefore, clinicians can see not only the presence of a biofilm, but also how thick it is and its position against the eardrum.

The research marks the first demonstration of using the ear OCT device to detect biofilms in human patients. To evaluate their device, the researchers worked with clinicians at Carle Foundation Hospital (Urbana, IL, USA), to scan patients with diagnosed chronic ear infections, as well as patients with normal ears. The device identified biofilms in all patients with chronic infections, while none of the normal ears showed evidence of biofilms.

“I think this is now a technology that allows physicians to monitor chronic ear infection, and examine better ways to treat the disease,” said Dr. Boppart, who is also affiliated with the departments of bioengineering and internal medicine, the Institute for Genomic Biology, and the Beckman Institute for Advanced Science and Technology at the U of I. “We can use different antibiotics and see how the biofilm responds.”

Next, the researchers plan to study different ear pathology, particularly comparing acute and chronic infections, and will examine the relationship between biofilms and hearing loss. They hope that improved diagnostics will lead to better treatment and referral practices.

The researchers plan to make their device--currently a hand-held prototype--even more compact, easy to use, and low-cost. The device company Welch Allyn (Skaneateles Falls, NY, USA), is a collaborator on the project, which was funded by the US National Institutes of Health (Bethesda, MD, USA).

Dr. Boppart’s group and its collaborators also will work to apply OCT imaging to other areas commonly examined by primary-care physicians. The ear-imaging device is the first in a suite of OCT-based imaging tools that the group plans to develop. Physicians could change the tip of the new OCT device, for example, to look at the eyes, mouth, nose, or skin.

“All the sites that a primary-care physician would look at, we can now look at with this more advanced imaging,” Dr. Boppart said. “With OCT, we are bringing to the primary-care clinic high-resolution 3D digital imaging and being able to look at many different tissue structures in real time, noninvasively, and in depth. As medicine gets more high-tech, we want to give the front-line doctor the best technology to detect disease early.”

Related Links:

University of Illinois at Urbana-Champaign
Welch Allyn



X-Ray Illuminator
X-Ray Viewbox Illuminators
New
Ultrasound Needle Guidance System
SonoSite L25
Radiology Software
DxWorks
Ultra-Flat DR Detector
meX+1717SCC

Channels

Ultrasound

view channel
Image: The new implantable device for chronic pain management is small and flexible (Photo courtesy of The Zhou Lab at USC)

Wireless Chronic Pain Management Device to Reduce Need for Painkillers and Surgery

Chronic pain affects millions of people globally, often leading to long-term disability and dependence on opioid medications, which carry significant risks of side effects and addiction.... Read more

Nuclear Medicine

view channel
Image: The diagnostic tool could improve diagnosis and treatment decisions for patients with chronic lung infections (Photo courtesy of SNMMI)

Novel Bacteria-Specific PET Imaging Approach Detects Hard-To-Diagnose Lung Infections

Mycobacteroides abscessus is a rapidly growing mycobacteria that primarily affects immunocompromised patients and those with underlying lung diseases, such as cystic fibrosis or chronic obstructive pulmonary... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.