Advanced Assistive Technology Predicts Organ Deformation during Radiotherapy

By MedImaging International staff writers
Posted on 06 Oct 2023
Print article
Image: A new technology can accurately predict organ deformation during radiation therapy (Photo courtesy of 123RF)
Image: A new technology can accurately predict organ deformation during radiation therapy (Photo courtesy of 123RF)

Radiation therapy is a popular choice for treating cancer and other conditions, largely because it's minimally invasive, allowing patients to quickly resume their normal lives. One issue, though, is that radiation can affect nearby healthy organs, particularly when high radiation doses are administered to diseased tissues in motion. While regular movements like breathing are somewhat predictable, irregular movements caused by the organ's interactions with neighboring organs can be hard to predict. The ability to precisely anticipate how organs move during radiation treatment is crucial for improving the therapy's effectiveness. Now, a new technology can capture real-time cross-sectional images of the affected area and use them to create three-dimensional (3D) motion of organs. This enables accurate predictions of the deformation of the pancreas and other organs depending on their position related to the nearby organs during radiation therapy.

Researchers from the University of Tsukuba (Ibaraki, Japan) have developed an innovative technique to determine the 3D movement of organs based on their relative positions to neighboring organs. This is done by acquiring real-time cross-sectional (2D) images of the targeted area from three different orientations during radiation therapy. Additionally, the researchers have created a cross-section selection system for picking the most accurate 2D image for further analysis.

The research team validated their technique using publicly accessible MRI data from 20 cases to evaluate the pancreas's position. When using data from just one angle, the error in locating the pancreas was 5.11 mm. However, when data from all three angles was employed, this error shrank dramatically to just 2.13 mm. In some cases, the accuracy was even comparable to what would be achieved if 3D information had been gathered beforehand. These findings could pave the way for radiation therapy protocols designed to minimize radiation exposure to nearby healthy organs, resulting in safer radiation therapy.

Related Links:
University of Tsukuba

Gold Member
Solid State Kv/Dose Multi-Sensor
AGMS-DM+
Ultrasound Doppler System
Doppler BT-200
New
1.5T MRI System
uMR 670
Ultrasound Needle Guide
Ultra-Pro II

Print article

Channels

MRI

view channel
Image: Diamond dust offers a potential alternative to the widely used contrast agent gadolinium in MRI (Photo courtesy of Max Planck Institute)

Diamond Dust Could Offer New Contrast Agent Option for Future MRI Scans

Gadolinium, a heavy metal used for over three decades as a contrast agent in medical imaging, enhances the clarity of MRI scans by highlighting affected areas. Despite its utility, gadolinium not only... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.