Dark-Field Chest Imaging Helps Diagnose Lung Disease

By MedImaging International staff writers
Posted on 06 Sep 2021
Print article
Image: Schematic of the prototype dark-field X-ray system (Photo courtesy of Radiology)
Image: Schematic of the prototype dark-field X-ray system (Photo courtesy of Radiology)
A new chest x-ray imaging technique can detect signals in the lungs that are undetected in standard chest x-rays, claims a new study.

Under investigation by researchers at Munich Technical University (TUM; Germany), Klinikum rechts der Isar (Munich, Germany), and Philips Research (Hamburg, Germany), x-ray dark-field imaging, unlike attenuation-based conventional radiography, utilizes the wave properties of x-rays, specifically the ultra-small-angle scattering that occurs at the material interface within the specimen. In analogy to dark-field light microscopy, dark field in this context refers to the bright appearance of scattering objects on a dark background.

Since the contrast is generated by multiple refractions on microstructures, healthy lungs have a relatively high signal due to their many air-tissue interfaces in the alveoli. Lung diseases interfering with the integrity of the alveolar structure, such as emphysema, fibrosis, and lung cancer, lead to a decrease in the dark-field signal. The researchers have developed a prototype system for humans that can be used to evaluate dark-field imaging for detection and characterization of lung diseases, with a comparably low amount of radiation exposure for the subject.

For the study, the researchers enlisted 40 healthy patients who underwent chest CT as part of their diagnostic workup, as well attenuation-based and dark-field chest radiographs simultaneously. The researchers found a correlation between total dark-field signal and the lung volume, with normal human lungs on dark-field chest x-ray imaging produced high signal, while the surrounding osseous structures had a low signal, and soft tissue produced no signal at all. In addition, no differences were found between men and women and age, weight, and height did not influence the dark-field signal. The study was published on August 24, 2021, in Radiology.

“Because of the nature of signal generation in dark-field imaging, bone structures and soft tissue generate only a minimal dark-field signal compared with lung tissue. This feature allows for a detailed depiction of lung tissue without impairment by surrounding structures,” concluded lead author Florian Gassert, PhD, of TUM, and colleagues. “These findings prove that the dark-field signal is indeed sensitive to the subject's lung condition alone and is independent from demographic factors, highlighting its potential value for diagnosis and monitoring of respiratory diseases.”

Related Links:
Munich Technical University
Klinikum rechts der Isar
Philips Research


Gold Member
Solid State Kv/Dose Multi-Sensor
AGMS-DM+
New
Ultrasound Doppler System
Doppler BT-200
New
Ultrasound Needle Guide
Ultra-Pro II
New
Ultrasound Table
Ergonomic Advantage (EA) Line

Print article

Channels

Nuclear Medicine

view channel
Image: The AI system uses scintigraphy imaging for early diagnosis of cardiac amyloidosis (Photo courtesy of 123RF)

AI System Automatically and Reliably Detects Cardiac Amyloidosis Using Scintigraphy Imaging

Cardiac amyloidosis, a condition characterized by the buildup of abnormal protein deposits (amyloids) in the heart muscle, severely affects heart function and can lead to heart failure or death without... Read more

General/Advanced Imaging

view channel
Image: The CIARTIC Move self-driving mobile C-arm has received FDA clearance (Photo courtesy of Siemens)

Self-Driving Mobile C-Arm Reduces Imaging Time during Surgery

Intraoperative imaging faces significant challenges due to staff shortages and the high demands placed on surgical teams in the operating room (OR). A common challenge during many OR procedures is the... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more

Industry News

view channel
Image: Samsung Medison CEO Mr. Yongkwan Kim and Bracco Imaging CEO Dr. Fulvio Renoldi Bracco endorsed a MoU agreement (Photo courtesy of Bracco Group)

Samsung and Bracco Enter Into New Diagnostic Ultrasound Technology Agreement

Samsung Medison (Seoul, South Korea) and Bracco Imaging (Milan, Italy) have entered into a Memorandum of Understanding (MoU) agreement to pioneer a new area for diagnostic ultrasound devices and contrast agents.... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.