Contrast-Enhanced 3D Ultrasound Used for Differentiating Focal Liver Lesions

By Medimaging International staff writers
Posted on 14 Jun 2010


A contrast-enhanced (CE) ultrasound (US) appeared as an important modality to show the vascularity in the areas of interest, and it has been used widely in clinical diagnosis of liver lesions. Three-dimensional ultrasonography (3D US) allows three orthogonal planes to spatially demonstrate the features of subjects, which has been frequently used in fetal US.

Different from the 2D images, CE 3D US acquires the data in a volume of interest (VOI) by automatically scanning with a desired angle and allows reconstruction of tomographic images in three orthogonal planes and renders angiogram-like images. The combination of 3D US and CE US can present the enhancement of lesions in three dimensions and also in parallel slices by multiple-planar visualization. Although many studies on differentiation among various focal liver tumors have been conducted using CE 2D US, and recently a few using CE 2D US with Sonazoid, the exact value of CE 3D US with Sonazoid in the differential diagnosis of various focal liver tumors has not yet been clarified. Sonazoid is manufactured by Nycomed Amersham Imaging (Princeton, NJ, USA).

A research article published in the May 7, 2010, issue of the World Journal of Gastroenterology addresses this question. The researchers, from the Gastroenterological Center, Yokohama City University Medical Center (Japan), retrospectively assessed tumor enhancement patterns, and the diagnostic criteria established using dominant enhancement patterns were then applied to differentiation among focal liver tumors in a prospective study.

In the study, with analysis of the combination of the enhancement in three phases at CE 3D US, the dominant patterns were used as the diagnostic criteria for individual category, and prospective differentiation yielded a good sensitivity, specificity, high Az value, and good to excellent inter-reader agreement, which revealed the potential usage of CE 3D US in differentiating various focal liver lesions. Although there were no significant differences between the prospective diagnosis at CE 3D US and that at CE 2D US, CE 3D US created a spatial and easily understood view for both hemodynamic and morphologic evaluation of focal liver tumors, which were formed only in the physicians' imagination by 2D imaging using complex acquisition methods.

The good to excellent inter-reader agreement in the investigators' previous study about CE 3D US demonstrating characteristic enhancement of hepatocellular carcinomas (HCCs) have indicated, according to the investigators, CE 3D US can exhibit the characteristic enhancement of HCC tumors objectively.

Related Links:
Gastroenterological Center, Yokohama City University Medical Center





Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to MedImaging.net and get complete access to news and events that shape the world of Radiology.
Free digital version edition of Medical Imaging International sent by email on regular basis
Free print version of Medical Imaging International magazine
(available only outside USA and Canada).
Free and unlimited access to back issues of Medical Imaging International in digital format
Free Medical Imaging International Newsletter sent every 2 weeks containing the latest news
Free breaking news sent via email
Free access to Events Calendar
Free access to LinkXpress new product services
REGISTRATION IS FREE AND EASY!


Click here to Register

Sign in: Registered website members
Username: Password:
Forgot username/password? Click here!
Sign in: Registered magazine subscribers
Subcode: Last Name:
What is SUBCODE?




Exam Viewer
Exam Viewer
Medical Diagnostic Monitor
Medical Diagnostic Monitor
Diagnostic System
Diagnostic System

More Products

SuperSonic Imagine
ECR
BAHIA SOFTWARE

Latest Ultrasound News

LinkXpress
Click for LinkXpress
Reader Inquiry Service
Enter code to receive information:
Where I can find code?
Featured Videos
Siemens Healthcare:


siemens.com/pink
More Videos
Featured Whitepaper
AGFA HEALTHCARE:
IMPAX Data Center and XERO technology help Louisiana Health System rebuild regional healthcare

Download Whitepaper
Events
KIMES 2012 - 28th Korea International Medical & Hospital Equipment Show
16 Feb 2012
19 Feb 2012


71st Annual meeting of Japan Radiological Society.
12 Apr 2012
15 Apr 2012


67th CMEF- China Medical Equipment Fair.
14 Apr 2012
17 Apr 2012


More events
GLOBETECH PUBLISHING
Latest Issue

View Digital Edition
Subscribe / Renew
GE HEALTHCARE'
ELSMED LTD - RELAXATION
RAMSOFT
EIZO GmbH Display Technologies
  medicalimaging.com Copyright © 2000-2012 Globetech Media. All rights reserved.
Privacy Policy