We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
GLOBETECH PUBLISHING LLC

Download Mobile App




Forensic Researchers Set Standards for X-Ray Identification

By MedImaging International staff writers
Posted on 12 Apr 2016
Print article
Image: Proximal femur concordant feature (Photo courtesy of Ann Ross/NCSU).
Image: Proximal femur concordant feature (Photo courtesy of Ann Ross/NCSU).
A new study establishes science-based standards for identifying human remains, based on X-rays of an individual's spine, upper leg, or the side of the skull.

Researchers at North Carolina State University (NCSU; Raleigh, USA), Middle Tennessee State University (Murfreesboro, USA), and the University of South Florida (USF; Tampa, USA) compared ante-mortem and post-mortem lateral craniofacial X-rays in 41 cases, X-rays of the vertebral column in 100 cases, and X-rays of the proximal femur in a further 49 cases. The X-rays were then scored for number of concordant features, analyzed using classification decision trees, and evaluated using a receiver operating characteristic.

The researchers then used the data to develop specific standards for each skeletal region. They used additional, unmatched X-rays to test the accuracy of the standards in accurately identifying a body, and how likely were false-positive or false-negative results. The outcome showed a wide spectrum of consistencies; for example, two or more points of concordance are required in lateral cranial X-rays for a 97% probability of a correct identification, with a 10% misclassification rate. And just a single concordant feature is needed on cervical vertebrae for a 99% probability of correct identification, with a 7% misclassification rate.

And if there are one or more femoral head and neck concordant features, the probability of a correct identification is 94% and 97%, respectively. However, at the other end of the spectrum, four or more concordant features are required for a 98% probability of correct identification, and even there is a 40% misclassification rate. The study also established the minimum number of concordant areas needed to confirm positive identifications in the three standard radiographic views. The study was published on March 17, 2016, in in the American Journal of Forensic Medicine and Pathology.

“In the past, forensic experts have relied on a mixed bag of standards when comparing ante-mortem and post-mortem X-rays to establish a positive identification for a body, but previous research has shown that even experts can have trouble making accurate identifications," said lead author Professor of Anthropology Ann Ross, PhD, of NCSU. “We've created a set of standards that will allow for a consistent approach to identification that can be replicated, and that allows experts to determine probabilities for an identification.”

Related Links:

North Carolina State University
Middle Tennessee State University
University of South Florida


Gold Member
Solid State Kv/Dose Multi-Sensor
AGMS-DM+
MRI System
uMR 588
Compact C-Arm with FPD
Arcovis DRF-C R21
New
Ultrasound Table
Powered Ultrasound Table-Flat Top

Print article

Channels

Nuclear Medicine

view channel
Image: The AI system uses scintigraphy imaging for early diagnosis of cardiac amyloidosis (Photo courtesy of 123RF)

AI System Automatically and Reliably Detects Cardiac Amyloidosis Using Scintigraphy Imaging

Cardiac amyloidosis, a condition characterized by the buildup of abnormal protein deposits (amyloids) in the heart muscle, severely affects heart function and can lead to heart failure or death without... Read more

General/Advanced Imaging

view channel
Image: The Cinematic Reality app enables interaction with realistic renderings of human anatomy (Photo courtesy of Siemens)

AR Application Turns Medical Scans Into Holograms for Assistance in Surgical Planning

Siemens Healthineers (Erlangen, Germany) has launched an app designed for Apple Vision Pro that allows users including surgeons, medical students, or patients to view immersive, interactive holograms of... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more

Industry News

view channel
Image: Samsung Medison CEO Mr. Yongkwan Kim and Bracco Imaging CEO Dr. Fulvio Renoldi Bracco endorsed a MoU agreement (Photo courtesy of Bracco Group)

Samsung and Bracco Enter Into New Diagnostic Ultrasound Technology Agreement

Samsung Medison (Seoul, South Korea) and Bracco Imaging (Milan, Italy) have entered into a Memorandum of Understanding (MoU) agreement to pioneer a new area for diagnostic ultrasound devices and contrast agents.... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.