Contradictory to mammography, recent findings have revealed breast-specific gamma imaging (BSGI), also known as molecular breast imaging (MBI), is as effective in identifying breast cancer in women with both dense and nondense breasts.

These findings were presented at the 2011 Radiological Society of North America (RSNA) annual meeting, held in Chicago (IL, USA), November 27-December 2, 2011. “Dense breast tissue is extremely common, occurring in 50% of premenopausal and 40% of postmenopausal women, and is a strong risk factor for developing breast cancer,” said Rachel Brem, MD, first author of this study from the George Washington University Medical Center (Washington DC, USA). “However, mammography is far less effective in women with dense breasts, missing 35%-45% of breast cancers in these women.”

Mammography in women with dense breasts is limited and necessitates additional imaging modalities that are not impacted by breast density. “As we increasingly appreciate the importance breast density has on risk for developing breast cancer and the limitations of mammography, it is crucial that we find technologies that allow for the detection of breast cancer, regardless of risk,” said Dr. Brem. “It is exciting that BSGI does exactly that and can be used to detect breast cancer in all women, regardless of density.”

Under new US legislation, mammography clinics in Connecticut and Texas are now required to inform patients about their breast density. While other states may follow suit, clinicians are already using advanced diagnostic imaging tools that are effective in the detection of cancer in both dense and nondense breasts.

Researchers from George Washington University Medical Center conducted a retrospective review of their BSGI database from January 2004 to August 2009. They evaluated 344 women with breast cancer, of whom breast density was available per mammography report. The study results revealed there was no difference in the sensitivity of BSGI/MBI in detecting breast cancer in women with nondense and dense breasts. The overall sensitivity of BSGI/MBI for breast cancer detection was 95.6%; 137 of 142 (96.5%) women with nondense breasts, and 192 of 202 (95.1%) women with dense breasts had positive BSGI/MBI examinations.

“The ability to utilize physiologic imaging to improve breast cancer detection is very exciting in that it is equally effective in women with dense and nondense breasts,” said Dr. Brem. “The sensitivity of BSGI has been reported to be equal to MRI, but BSGI is performed with the patient comfortably seated. BSGI requires a fraction of the physician time for image interpretation, has a lower false-positive rate, and can be performed in women who cannot undergo MRI [magnetic resonance imaging], such as those with implantable devices and renal insufficiency. The integration of BSGI in clinical practice is a robust tool for the improved detection of the smallest cancers: those which are detected early, and are most curable,” said Dr. Brem.

As a follow-up to mammography, BSGI/MBI utilizes the Dilon (Newport News, VA, USA) 6800 gamma camera to help physicians more clearly distinguish benign from malignant tissue. To perform BSGI/MBI, the patient receives a pharmaceutical tracing agent that is absorbed by all the cells in the body. Due to their increased rate of metabolic activity, cancerous cells in the breast absorb a greater amount of the tracing agent than normal healthy cells and typically appear as dark spots on the BSGI/MBI image.

Related Links:
George Washington University Medical Center
Dilon




Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to MedImaging.net and get complete access to news and events that shape the world of Radiology.
Free digital version edition of Medical Imaging International sent by email on regular basis
Free print version of Medical Imaging International magazine
(available only outside USA and Canada).
Free and unlimited access to back issues of Medical Imaging International in digital format
Free Medical Imaging International Newsletter sent every 2 weeks containing the latest news
Free breaking news sent via email
Free access to Events Calendar
Free access to LinkXpress new product services
REGISTRATION IS FREE AND EASY!


Click here to Register

Sign in: Registered website members
Username: Password:
Forgot username/password? Click here!
Sign in: Registered magazine subscribers
Subcode: Last Name:
What is SUBCODE?

ADVERTISEMENT
GLOBETECH PUBLISHING



Diagnostic Ultrasound System
Diagnostic Ultrasound System
X-Ray Film Processor
X-Ray Film Processor
Mobile C-Arm System
Mobile C-Arm System

More Products

BAHIA SOFTWARE
ELSMED LTD - RELAXATION
SuperSonic Imagine

Latest Nuclear Medicine News

LinkXpress
Click for LinkXpress
Reader Inquiry Service
Enter code to receive information:
Where I can find code?
Featured Videos
Siemens Healthcare:


siemens.com/pink
More Videos
Featured Whitepaper
AGFA HEALTHCARE:
IMPAX Data Center and XERO technology help Louisiana Health System rebuild regional healthcare

Download Whitepaper
Events
50th Annual Meeting and 36th post Graduate Course of the European Society of Paediatric Radiology (E
03 Jun 2012 - 07 Jun 2012


UKRC – UK Radiology Congress.
25 Jun 2012 - 26 Jun 2012


FIME 2012 – Florida International Medical Exhibition.
08 Aug 2012 - 10 Aug 2012


More events
Latest Issue

View Digital Edition
Subscribe / Renew
EIZO GmbH Display Technologies
RAMSOFT
GLOBETECH PUBLISHING
  medicalimaging.com Copyright © 2000-2012 Globetech Media. All rights reserved.
Privacy Policy