Print article
Investigators, expanding on earlier studies, reported that individuals with balance disorders or dizziness traceable to an inner-ear disturbance show distinctive abnormal eye movements when the affected ear is exposed to the strong pull of a magnetic resonance imaging scanner’s (MRI) magnetic field.

The researchers first reported in 2011 in the journal Current Biology that an MRI’s magnetic field pushes on the inner ear fluid responsible for maintaining balance, causing subjects undergoing MRI scans to have jerky eye movements and dizziness. Two new studies now suggest that these strong magnets could be used to diagnose, treat and study inner ear disorders in the future, replacing more invasive and uncomfortable examinations.

In the first study, reported online March 13, 2014, in the journal Frontiers in Neurology, a team led by Bryan Ward, MD, a resident in the department of otolaryngology-head and neck surgery at the Johns Hopkins University School of Medicine (Baltimore, MD, USA), placed nine patients with balance problems in an MRI machine and took video of their eye movements, without taking any MRI images.

Their earlier research had shown that healthy study participants subjected to a 7 Tesla magnetic field—the strength of the most modern MRI scanner—experienced a distinctive eye movement called nystagmus, in which the eyes repeatedly drift to one side and then jerk back. This time, the researchers were curious whether this movement might look different in patients with inner ear problems, whose semicircular canals would likely react differently to the MRI magnet’s pull.

While healthy, normal volunteers’ eyes moved side to side when in the MRI, with the direction of movement dependent on whether they entered the MRI tunnel head or feet first, people with “one-sided” inner ear problems displayed different eye movements that depended on which ear was affected. For example, according to Dr. Ward, the eyes of patients whose left ear was affected drifted down and jerked up when put into the MRI tunnel head first. Those whose right ear was affected had an opposite movement. Both sets of patients showed patterns of rapid eye motions not seen in the healthy volunteers.

Because the abnormal findings consistently showed which ear was affected in the patients, according to Dr. Ward, researchers may eventually be able to use magnetic stimulation to diagnose the cause of balance disorders. Currently, people whose dizziness or imbalance is suspected to originate in the inner ear may have eye movements measured after being spun around in a chair, tilted backward on special tables, or subjected to at times uncomfortable ear canal irrigation with cold or warm water.

Magnetic stimulation, acting as a virtual reality stimulator, could also offer an alternative to traditional physical therapy for balance disorders, which often involve rapid head movements that make patients dizzy. “Using magnetic stimulation, perhaps in a portable device that could fit in a doctor's office, could offer an alternative that’s more comfortable,” Dr. Ward stated.

In a second study, published March 19, 2014, in the journal PLOS One, Dr. Ward and his colleagues set out to investigate whether the inner ear balance systems of zebrafish are also influenced by magnetic stimulation. Zebrafish are a prevalent model for genetics and pharmaceutical studies of hearing and balance because of their surprising anatomical similarity to humans’ vestibular systems, according to Dr. Ward.

If the inner ears of these fish were also affected by a strong magnet’s pull, he says, these animals could eventually be a useful tool for studying which genes are involved in inherited inner ear balance problems or which drugs could be used to treat these disorders. To study this, the researchers placed 30 healthy zebrafish, one at a time, into a very strong 11.7 Tesla magnetic field, using a smaller MRI machine to better accommodate the aquarium used to hold each fish.

When the aquarium was in the magnetic field, the majority of fish responded in a dramatic way akin to the vertigo and imbalance that humans with inner ear system disturbances show: The fish flipped, rolled and swam faster than normal. The fish reverted to normal swimming behavior only when their aquarium was taken out of the MRI machine and away from the magnet.

To ascertain that this behavior was not due to any vision changes or effects on the lateral line—an organ on the side of the body of a fish important for helping the animals maintain posture or sense electrical currents in the water—the researchers turned lights on and off every 30 seconds while the fish were in the magnetic field and also had them swim in the magnetic field after they had been exposed to gentamicin, an antibiotic that destroys lateral line cells. Neither experiment changed the animals’ strange swimming behavior in the magnetic field.

The researchers additionally observed that individual fish seemed to be affected by the orientation of the magnetic field, swimming preferentially either in the direction of the magnetic field or in an opposite orientation. For instance, some of the animals preferred to swim north-south in a north-south field, while others chose to swim east-west. Putting the animals into an opposing field did not affect their preference. These results could add insight into the scientific field of magnetosensation, which studies how some animals are able to sense the Earth’s magnetic field and use it for purposes such as migration, Dr. Ward noted.

Overall, the findings in humans and fish could eventually lead to useful ways to harness the effect of an MRI magnet on the inner ear. “We may someday have some practical applications for this anatomical oddity,” Dr. Ward said.

Related Links:

Johns Hopkins University School of Medicine



Gold Member
Solid State Kv/Dose Multi-Sensor
AGMS-DM+
New
Pre-Op Planning Solution
Sectra 3D Trauma
New
Ultrasound System
P20 Elite
Ultrasound Software
UltraExtend NX

Print article
Radcal

Channels

Nuclear Medicine

view channel
Image: The new SPECT/CT technique demonstrated impressive biomarker identification (Journal of Nuclear Medicine: doi.org/10.2967/jnumed.123.267189)

New SPECT/CT Technique Could Change Imaging Practices and Increase Patient Access

The development of lead-212 (212Pb)-PSMA–based targeted alpha therapy (TAT) is garnering significant interest in treating patients with metastatic castration-resistant prostate cancer. The imaging of 212Pb,... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.